Products

 

ZKRV-50C REDUCER


50C正.png     50C.png

                      50C   Front                                                    50C back



Technical Parameters

 


Table 1 Operating parameter

 Oouput Rotational speed

             r/min

 

Model

5

15

25

35

Output torque

Input capacity

Output torque

Input capacity

Output torque

Input capacity

Output torque

Input capacity

Nm

kW

Nm

kW

Nm

kW

Nm

kW

50C

680

0.48

490

1.03

420

1.47

375

1.57

Note: the rated torque is the output torque when the output speed is at 15r/min.


 Table 2 Performance Parameter

Model

Speed ratio

Allowable output speed

Maximum backlash

Allowable acceleration/decleration torque

Momentary max allowable torque

Allowable moment

Momentary max allowable movement

Weight

Efficiency

Noise

r/min

arc.min

Nm

Nm

Nm

Nm

kg

%

dB

50C

32.54

50

1

1225

2450

1760

3500

15

>80

<75

 

Table 3 Installation parameter

inner hexagon bolt

    Nominal dimension x pith(mm)

fastening torque(Nm)

fastening force(N)

bolt requirement

M10×1.5

73.5±3.43

38080

GB/T 70.1-2000

intensity class12.9

thread requirementGB/T 1167-1996

 


Installation drawings


50C.jpg